Abstract

Tubular systems rank among the most effective ways of resisting lateral loads in tall buildings, because the main load-bearing material is concentrated at the outer edge of the building, which then behaves like a hollow cantilever tube under wind and earthquake action. This review examines the fundamental characteristics of the principal tubular configurations, namely the framed, bundled, braced and diagrid forms. It covers several key features of the different types of tubular structures which include lateral stiffness, storey drift, shear lag, axial force distribution, overturning moment, structural behavior under wind and seismic loads, material efficiency, and architectural considerations. As framed tube systems suffer from a phenomenon called shear lag, reducing their efficiency in tall structures, while bundling tubes eliminate shear lag with internal webs and braced tubes and diagrid systems provide shear resistance through the axial load of the diagonal members.

Keywords:Tubular structuresHigh-rise buildingsFramed tubeBundled tubeBraced tubeDiagridShear lagLateral load resistance.

References

1.Ali, M. M., & Moon, K. S. (2007). Structural developments in tall buildings: current trends and future prospects. Architectural science review, 50(3), 205-223.
2.Ali, M. M., & Moon, K. S. (2018). Advances in structural systems for tall buildings: emerging developments for contemporary urban giants. Buildings, 8(8), 104.
3.Ali, M. M., & Al-Kodmany, K. (2022). Structural systems for tall buildings. Encyclopedia, 2(3), 1260-1286.
4.Gunel, M. H., & Ilgin, H. E. (2007). A proposal for the classification of structural systems of tall buildings. Building and environment, 42(7), 2667-2675.
5.Kwan, A. K. (1994). Simple method for approximate analysis of framed tube structures. Journal of Structural Engineering, 120(4), 1221-1239.
6.Mazinani, I., Jumaat, M. Z., Ismail, Z., & Chao, O. Z. (2014). Comparison of shear lag in structural steel building with framed tube and braced tube. Structural Engineering and Mechanics, 49(3), 297-309.
7.Moon, K. S., Connor, J. J., & Fernandez, J. E. (2007). Diagrid structural systems for tall buildings: characteristics and methodology for preliminary design. The structural design of tall and special buildings, 16(2), 205-230.
8.Mele, E., Toreno, M., Brandonisio, G., & De Luca, A. (2014). Diagrid structures for tall buildings: case studies and design considerations. The Structural Design of Tall and Special Buildings, 23(2), 124-145.
9.Moon, K. S. (2008). Optimal grid geometry of diagrid structures for tall buildings. Architectural Science Review, 51(3), 239-251.
10.Mashhadiali, N., Molaei, F., & Siavoshi, H. (2021, December). Investigation of shear lag effect in tall tube-type buildings. In Structures (Vol. 34, pp. 4204-4215). Elsevier.
11.Kim, J., & Lee, Y. H. (2012). Seismic performance evaluation of diagrid system buildings. The Structural design of tall and special buildings, 21(10), 736-749.
12.Zhang, C., Zhao, F., & Liu, Y. (2012). Diagrid tube structures composed of straight diagonals with gradually varying angles. The Structural Design of Tall and Special Buildings, 21(4), 283-295.
13.Liu, C., Li, Q., Lu, Z., & Wu, H. (2018). A review of the diagrid structural system for tall buildings. The Structural Design of Tall and Special Buildings, 27(4), e1445.
14.Mashhadiali, N., & Kheyroddin, A. (2013). Proposing the hexagrid system as a new structural system for tall buildings. The Structural Design of Tall and Special Buildings, 22(17), 1310-1329.
15.Elshaer, A., Bitsuamlak, G., & El Damatty, A. (2017). Enhancing wind performance of tall buildings using corner aerodynamic optimization. Engineering structures, 136, 133-148.
16.Baker, W. F., Korista, D. S., & Novak, L. C. (2007). Burj Dubai: Engineering the world's tallest building. The structural design of tall and special buildings, 16(4), 361-375.
17.Ahmad Abdelrazaq, S. C. T. (2012). Validating the structural behavior and response of Burj Khalifa.
18.Liu, C., Fang, D., Zhao, L., & Zhou, J. (2022). Seismic fragility estimates of steel diagrid structure with performance-based tests for high-rise buildings. Journal of Building Engineering, 52, 104459.
19.Naik, S., & Modhera, C. D. (2024, December). Innovative Structural Systems for Tall Tilted Buildings Utilizing Diagrid and Hybrid Diagrid Configuration Under Lateral Loads. In International Conference on Recent Advances in Structural Engineering (pp. 131-140). Singapore: Springer Nature Singapore.
20.Asadi, E., & Adeli, H. (2017). Diagrid: An innovative, sustainable, and efficient structural system. The Structural Design of Tall and Special Buildings, 26(8), e1358.

Cite This Article
APA 7th Edition
Lateef Khan & Prof. Ashish Shrivas (2026). A COMPREHENSIVE REVIEW OF THE STRUCTURAL BEHAVIOUR AND LATERAL LOAD RESISTANCE OF TUBULAR STRUCTURAL SYSTEMS IN HIGH-RISE BUILDINGS. RICERCA, INTERNATIONAL JOURNAL OF MULTIDISCIPLINARY RESEARCH AND INNOVATION, 6(11), 9-15. https://rijmri.com/article/a-comprehensive-review-of-the-structural-behaviour-and-lateral-load-resistance-of-tubular-structural-systems-in-high-rise-buildings/